ENERSOL SYSTEM:
* The ENERSOL system is not potable water compatible, not recommended for use with Glycol,and cannot be used in a pressurized water system.
* Covering the panels with glazing (plexiglass or glass) is not recommended
The ENERSOL system is not designed for winter use.
PLUMBING TECHNICAL TIPS:
* Use PVC pipe for plumbing, ABS is not UV stable and will degrade with outdoor use.
* Use Weld on 711 PVC cement – or a heavy-bodied PVC cement with pipe joints
* Ensure plumbing is straight, and properly fit – measure twice cut once
* At any low points in plumbing, use a tee and end cap. This will allow for drainage
* If plumbing a substantial distance underground, insulate the pipe.
* A pressure relief valve is not required on an Enersol system
* do not install panels below the level of the pool – bottom row of headers should not
be below the bottom of the pool.
| Pump Size (Horsepower) | Mimimum Sections | ||
| 3/4 hp | 9 sections | ||
| 1 hp | 12 sections | ||
| 1 1/2hp | 18 sections | ||
| 2 hp | 24 sections |
If the system is undersized, or the pump is larger, follow by-pass
instructions. ( see DIY information)
* to determine pump size – 1 psi raises water 27″ in 1 1/2″ pipe
| Flow Rates |
| Recommended pump size: 3/4-1hp |
| Recommended operating pressure: 15 PSI@120F |
| Maximum fluid pressure: 20PSI @120F |
| Recommended Flow Rate: 4-10 GPM per 4′ width |
| 90 elbow adds 6′ to 1 1/2″ pipe |
| 45 elbow adds 2′ to 1 1/2″ pipe |